Home ProductsHonda Accord Hybrid Battery

Vehicle Honda Accord Hybrid Battery / Car Battery For 2005 Honda Accord

I'm Online Chat Now

Vehicle Honda Accord Hybrid Battery / Car Battery For 2005 Honda Accord

China Vehicle Honda Accord Hybrid Battery / Car Battery For 2005 Honda Accord supplier
Vehicle Honda Accord Hybrid Battery / Car Battery For 2005 Honda Accord supplier Vehicle Honda Accord Hybrid Battery / Car Battery For 2005 Honda Accord supplier

Large Image :  Vehicle Honda Accord Hybrid Battery / Car Battery For 2005 Honda Accord

Product Details:

Place of Origin: China
Brand Name: Hyno
Certification: ISO/TS16949:2009, ISO9001:2008
Model Number: Hyno Accord 144

Payment & Shipping Terms:

Minimum Order Quantity: 1 pack
Price: To be discussed
Packaging Details: Standard packing, paper box, wooden box
Delivery Time: To be discussed
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100000 packs/month
Detailed Product Description
Nominal Voltage: 7.2V Chemistry Of Battery: NiMH
Cycle Life: ≥1000cycles Battery Pack Voltage: 144V
Electronics Included: Yes Programming Required: No
High Light:

honda accord battery replacement

,

honda accord car battery

Hyno Energy. Honda Accord Hybrid Battery (2005-2007). 6500mAh 144V, Competent Performance

If we use 200 cells as an average per pack. For every 1 million hybrids, there are 200 million individual NiMH cells. Multiply that by seven, and the world has a supply of 1.4 billion cells in use. And we are adding over 250 million cells per year.

Hybrid car batteries consist of many cells that are connected in series and packed into a container (plastic or metal). These are called modules, cassettes or sticks depending on the manufacturer. Many modules are packaged into “packs,” and many subsystems support the pack. Cooling, heating, voltage and amperage management, high voltage leak detection and relays are added to ensure a long, safe life.

Qaulity Warranty

Product fabrication and material defects are guaranteed within 2 years.

Recommendations: the company's products have been filled 30-90% power in the factory, depending on the shipping distance and packing conditions. When capacity measurement, discharge with 1C to 6.3V/ stick; then charge/discharge with the specified current to test capacity. If the stock reach or exceed 2 months, discharge with 1C to 7.2V/ stick; Then charge with 1C for 51min, 0.2C charge for 1hrs, rest 20min, discharge with 1C to 6.3V/ stick, after 3 cycles; Then charge/discharge with the specified current to test capacity. For the first use, the standard charge method is recommended to avoid damage to the battery.

Technical Specification

Battery Module
Description Original Replacement
Voltage 7.2V 7.2V
Capacity 6.5Ah 6.5Ah
Length 380mm 380mm
Net Weight 1040g

1040g

 

The whole battery pack consisted by 20 set of above modules

 

 

Item Specification
Dimension Length (mm) × Width (mm) × Height (mm) 290 x 294 x 110
Approximate Weight (kg) 30
Typical Capacity(mAh) 6500
Minimum Capacity (mAh) 6000
Nominal Voltage (V) 144
High Temperature Performance ( 55℃ 1C discharge rate) ≥90%
Low Temperature Performance (-20℃ 1C discharge rate) ≥85%
Charge Retention Performance (28days charge retention rate) ≥80%
Working Temperature Range -20℃ to +55℃
Cycle Life (C/2 charge, 1C discharge) ≥1000cycles
     

 

Cautions of Battery Pack Transportation and Storage

  1. Avoid violent vibration and external force impact, don’t cast, roll, invert, extrude, and stack too high during handling and transportation of battery pack.
  2. Protect the battery pack from rain during the transportation, and the ambient temperature is not over 55℃.
  3. Store the battery pack in a cool and dry place and the temperature range is 5-25℃ when you are not using it.

Maintenance regulations (Maintain the whole battery pack, and cool with a fan during the charge and discharge process)

The SOC of our battery pack is 60%~80% when leaving the factory, in long-term storage, battery should be stored in a charged state (usually the SOC is 80%). Have a charge and discharge maintenance to battery pack when the storage time is over 6 months or battery module’s voltage is 15V,to prevent the battery performance’s decline caused by the self-discharge. The maintenance regulations are as follows:

  1. Discharge: 2A discharge to 204V (that is to say: single cell 1.0V)
  2. Interval: 30 minutes
  3. Charge: 1.3A charge for 5 hours (voltage ≥ 306V, -ΔV ≥ 0.2V and temperature ≥50℃)
  4. Interval: 1hours
  5. Discharge: 2A discharge to 204V (that is to say: single cell 1.0V)
  6. Interval: 30 minutes
  7. Charge: 2A charge for 2.4 hours

Installation Cautions of battery pack

Notes: Installing this product should only be attempted by a qualified technician, the voltage of the battery pack is very high, which has the shock hazards, so when installing the battery pack, you should wear insulating gloves and use insulated handle tools.

  1. Please operate according to assembly manual during the installation of Prius battery pack.
  2. Do not mix our battery modules with those of other manufacturers, or new battery modules in use with semi-used battery modules, and don’t mix battery modules within a battery pack with those in other battery pack.
  3. Don’t twist and bend battery modules and accessories when assembling battery pack.
  4. Don’t connect the anode and cathode of battery module in reverse when assembling battery pack, to prevent short circuits.
  5. Fasten bolts and nuts with appropriate torque, avoid loose connection or damaging other accessories with too big torque.

Use Cautions of battery pack

  1. Ensure the normal operation of car management system during the use process, and forbid over- charge and over-discharge to battery.
  2. As storage battery is charged by gasoline engine, so external power supply charge is not needed. However, if the vehicle parks for a long time, the electricity of high power storage battery will run out. Therefore, be sure to drive the car for at least 30minutes or 16Km every several months.
  3. If there is leaked liquid, don’t touch the spilled liquid, because this may be the alkaline electrolyte that hybrid battery leaks. If skin and eyes contact to this liquid, please flush with plenty of water at once, or if possible, wash with boric acid solution and see the doctor at once.

 

Appendix

 

Hunan Hi-soon Supply Chain Co., Ltd reserves the right to change and revise Product specification without any advance notice.

Contact Details
Hunan Hi-soon Supply Chain Co.

Contact Person: Aaron Xiang

Tel: 008615675823200

Send your inquiry directly to us (0 / 3000)