Home ProductsHonda Insight Hybrid Battery

100.8V 2010 Honda Insight Battery Replacement 7 Sets Modules Long Life

I'm Online Chat Now

100.8V 2010 Honda Insight Battery Replacement 7 Sets Modules Long Life

China 100.8V 2010 Honda Insight Battery Replacement 7 Sets Modules Long Life supplier
100.8V 2010 Honda Insight Battery Replacement 7 Sets Modules Long Life supplier 100.8V 2010 Honda Insight Battery Replacement 7 Sets Modules Long Life supplier

Large Image :  100.8V 2010 Honda Insight Battery Replacement 7 Sets Modules Long Life

Product Details:

Place of Origin: China
Brand Name: Hyno
Certification: ISO/TS16949:2009, ISO9001:2008
Model Number: Hyno Insight 101

Payment & Shipping Terms:

Minimum Order Quantity: 1 pack
Price: To be discussed
Packaging Details: Standard packing, paper box, wooden box
Delivery Time: To be discussed
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100000 packs/month
Detailed Product Description
Nominal Voltage: 100.8 Volt Minimum Capacity: 6000aAh
Cycle Life: ≥1000cycles Type Of Battery: NiMH
Vehicle Fit: Honda Insight MOQ: One Pack
High Light:

2010 honda insight battery

,

2012 honda insight battery

Hyno Energy. 100.8V by 7 Sets of Battery Modules, Replacement For Honda Insight (2006-2012). 6500mAh 144V

Although hybrid cars have been breathtakingly dependable, there is a limit to the life of nickel-metal hydride battery packs. While some hybrid vehicle owners had to replace batteries at 70,000 miles, others have gotten as much as 200,000 miles out of their original units. Toyota has said even 300,000 or 400,000 miles on one set of Prius batteries is possible.

Test Condition:

This specification is applicable to Ni MH battery for hybrid produced by Hunan Hi-soon Supply Chain Co., Ltd.,

Hunan Hi-soon Supply Chain Co., Ltd reserves the right to change and revise Product specification without any advance notice.

Tests should be done within one month of receiving the goods under the following conditions.

Test condition

Temperature:20±5℃

Relative Humidity:65±20%

Atmospheric Pressure:86~106kPa

Standard charge discharge specification

Discharge: 6000mA (1C) to 12.0V

Charge: 6000mA (1C)×1hrs,1200mA (0.2C)×1hrs

Discharge: 6000mA (1C) to 12.0V

Technical Specification

No. Description Unit Specification Condition
1 Nominal Voltage V 14.4  
2 Operating Voltage V 6.0~9.6  
3 Nominal capacity mAh 6500 Standard charge / discharge
4 Minimum capacity mAh 5800 Standard charge / discharge
5 Nominal Energy Wh 90 1 hour rate
6 Weight g 2000±50 Standard environment,Accuracy±0.05g Electronic scale
7 Power Density W/kg >850  
8 Energy Density Wh/kg >43  
9 Max. continuous discharge current C 20 20℃~45℃
10 Max. continuous charge current C 15
11 Storage Temperature -20~35  
12 Operating Temperature -30~55  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cautions of Battery Pack Transportation and Storage

  1. Avoid violent vibration and external force impact, don’t cast, roll, invert, extrude, and stack too high during handling and transportation of battery pack.
  2. Protect the battery pack from rain during the transportation, and the ambient temperature is not over 55℃.
  3. Store the battery pack in a cool and dry place and the temperature range is 5-25℃ when you are not using it.

Maintenance regulations (Maintain the whole battery pack, and cool with a fan during the charge and discharge process)

The SOC of our battery pack is 60%~80% when leaving the factory, in long-term storage, battery should be stored in a charged state (usually the SOC is 80%). Have a charge and discharge maintenance to battery pack when the storage time is over 6 months or battery module’s voltage is 15V,to prevent the battery performance’s decline caused by the self-discharge. The maintenance regulations are as follows:

  1. Discharge: 2A discharge to 204V (that is to say: single cell 1.0V)
  2. Interval: 30 minutes
  3. Charge: 1.3A charge for 5 hours (voltage ≥ 306V, -ΔV ≥ 0.2V and temperature ≥50℃)
  4. Interval: 1hours
  5. Discharge: 2A discharge to 204V (that is to say: single cell 1.0V)
  6. Interval: 30 minutes
  7. Charge: 2A charge for 2.4 hours

Installation Cautions of battery pack

Notes: Installing this product should only be attempted by a qualified technician, the voltage of the battery pack is very high, which has the shock hazards, so when installing the battery pack, you should wear insulating gloves and use insulated handle tools.

  1. Please operate according to assembly manual during the installation of Prius battery pack.
  2. Do not mix our battery modules with those of other manufacturers, or new battery modules in use with semi-used battery modules, and don’t mix battery modules within a battery pack with those in other battery pack.
  3. Don’t twist and bend battery modules and accessories when assembling battery pack.
  4. Don’t connect the anode and cathode of battery module in reverse when assembling battery pack, to prevent short circuits.
  5. Fasten bolts and nuts with appropriate torque, avoid loose connection or damaging other accessories with too big torque.

Use Cautions of battery pack

  1. Ensure the normal operation of car management system during the use process, and forbid over- charge and over-discharge to battery.
  2. As storage battery is charged by gasoline engine, so external power supply charge is not needed. However, if the vehicle parks for a long time, the electricity of high power storage battery will run out. Therefore, be sure to drive the car for at least 30minutes or 16Km every several months.
  3. If there is leaked liquid, don’t touch the spilled liquid, because this may be the alkaline electrolyte that hybrid battery leaks. If skin and eyes contact to this liquid, please flush with plenty of water at once, or if possible, wash with boric acid solution and see the doctor at once.

Quality warranty

  1. The battery is guaranteed for 36 months or 50000km from the date leaving the factory, whichever comes first.
  2. If quality problem occurs within the warranty period, we are responsible for changing the damaged battery modules(Customers need to provide related battery modules information)
  3. The battery is not within the warranty range in the following situation:
  1. The battery damage caused by failing to in accordance with the provisions of the transport, storage, installation and using.
  2. The battery damage caused by an external force (such as traffic accidents, natural disasters) or by external short circuit during using process.
  3. The battery damage caused by the out of control of BMS.

Contact Details
Hunan Hi-soon Supply Chain Co.

Contact Person: Aaron Xiang

Tel: 008615675823200